缺氧
85 个评价
Configurable Heaters
3
   
奖励
收藏
已收藏
取消收藏
文件大小
发表于
更新日期
259.854 KB
2022 年 9 月 28 日 上午 8:55
2024 年 9 月 2 日 下午 12:26
8 项改动说明 ( 查看 )

订阅以下载
Configurable Heaters

在 Daron 的 1 个合集中
Daron's Tweaks
13 件物品
描述
Configurable Heaters
This mod adds configuration options for Space Heater and Liquid Tepedizer


You can adjust the target temperature for space heater and liquid tepedizer
You can also adjust heating and wattage cost for liquid tepedizer. Heating/wattage controls for space heater have been reworked in the newest patch and are harder to change.


This mod is safe to use on existing saves and uninstalling this mod reverts all it's changes back to vanilla.

Source code on github[github.com]
This mod uses PeterHan library under MIT license[licenses.nuget.org]
46 条留言
Marideria 5 月 30 日 上午 10:20 
at 1 to 1 settings, with perfect isolation and self cooling turbine setup, tepedizer should be able to power itself with tubine indefenetly, with no energy loss... but scince its round down by a bit, it will eventually stop.
Marideria 5 月 30 日 上午 10:14 
Steam turbine=877590/850=1032.46 dtu/w +10% dtu back as heat.
1032.46*0.8 = 825.968 dtu/w at 80%.
Good balanced option... double the stats we get 1,651.936, or round up to 1652 kDTU heating at 1920 watts with unlimited temperature.

Or if we consider lossless energy conversion, as turbine does leak heat, and therefore it will be impossible to gain power even with 1 to 1 ratio:
Steam turbine=877590*0.9/850=929.21 dtu/w
929.21 multiply by deisred power, best option would be 2 kw, so 1,858,420 dtu, or round down to 1858 heating at 2000 wattage, is another setting that makes sence.
1784 heating at 1920 wattage, or 892 at 960 for default wattage, all with conservation of energy at turbines power baseline.
BRACK/MOUTH 2 月 8 日 下午 4:30 
oh. whoops. i subbed to this w/o reading enough, i thought it also let you change the KDTU and power of the space heater, but it only does that for the tepedizer
fatherg.m 1 月 15 日 下午 2:20 
is it working?
Daron  [作者] 2024 年 9 月 2 日 下午 12:27 
Should be fixed now
Clamor_S 2024 年 8 月 10 日 上午 8:34 
liquit tepidizer target temperature and heat generation in kDTU are swapped in config. Please adjust your mod.
Daron  [作者] 2024 年 7 月 26 日 上午 2:39 
The fix is live
LauraTons 2024 年 7 月 21 日 下午 7:46 
I didnt realize that customizable buildings mod also has this functionality now. so i dont know if they were also conflicting or not...
LauraTons 2024 年 7 月 21 日 下午 6:08 
Can also agree, the mod now doesnt work as intended. makes the heater freeze and target the same temp. so it basically doesnt work ever. Needs an update :/
Sif 2024 年 7 月 21 日 上午 9:26 
mod is borked