FortressCraft Evolved

FortressCraft Evolved

评价数不足
Soft Resin Ablator
   
奖励
收藏
已收藏
取消收藏
文件大小
发表于
更新日期
19.530 KB
2019 年 2 月 7 日 上午 8:35
2019 年 7 月 23 日 上午 3:25
10 项改动说明 ( 查看 )

订阅以下载
Soft Resin Ablator

描述
This mod adds Soft Resin Ablator!

It will unlock the same time as normal Resin Ablator and will cost the same.
Machine will ablate soft resin into ablated resin, from there use vanilla liquifier.

This machine takes Compressed Freezon Canisters from adjacent hopper to super charge ablation!
It works just like freezon injector for vanilla ablator. (20 super charged shoots)
Additionally for non-DLC people, it accepts Composite Fuel, it's 4x weaker than freezon. (5 shoots)



Mod ID: 1647833740
18 条留言
Wariat117  [作者] 2019 年 7 月 23 日 上午 3:29 
Oki, the bug should be fixed now.
This bug was caused by the fix for the negative numbers.

I have had to find new fix for negative numbers, and I have found out that the game (on random occurances) was using more power than 625 o-o
And that if ablator went negative power it started to "cool down" the ablation process, because of this machine was going into infinite negative power (keeps cooling down and keeps using power)
Now everything should be ok.
Wariat117  [作者] 2019 年 7 月 23 日 上午 1:31 
Oki, now I have managed to reproduce it, if you cut off power source when machine is on low power then machine will interrupt abalting if power drops under 625, and won't ablate until you bring more power
Austin5003 2019 年 7 月 23 日 上午 1:18 
I get that, but it stops the process if it already started ablating
Wariat117  [作者] 2019 年 7 月 23 日 上午 1:13 
It's supposed to not ignore it.
It's supposed to wait until you have enough power to ablate...
Austin5003 2019 年 7 月 23 日 上午 1:12 
The ablator just isn't ignoring the minimum power requirement when it's processing a block
Austin5003 2019 年 7 月 23 日 上午 1:06 
When the ablator gets low on power, it gets interrupted instead of using up the last >625 power required, and the loop only ends up happening with low input rates
Wariat117  [作者] 2019 年 7 月 23 日 上午 12:47 
Would you mind giving more informations? Are you on default settings? (maybe non default requires different amount of power?) Screenshots of your setup?
I couldn't reproduce it.

The machine doesn't start ablating unless there is enough power to finish it, it doesn't use the power when it's waiting.
I have had 3 ablators on single soft resin block, ablating it at the same time, they all ablated it (and used power too) and moved onto next block, none of them was stuck on the partially ablated soft resin. (first I have made them all wait looking at the same soft resin and then injected power)
Austin5003 2019 年 7 月 21 日 下午 10:32 
And even after that partially ablated block is processed by another ablator, the soft ablator will still continuously fire at those coordinates
Austin5003 2019 年 7 月 21 日 下午 10:30 
The ablator needs to ignore the minimum power storage requirement when it's in the process of ablating a block, otherwise it will get stuck in a loop where it wastes power
Wariat117  [作者] 2019 年 4 月 16 日 下午 10:51 
It's miracle, someone actually reported anything :D

I couldn't reproduce it so I have released "maybe-fix" (it will maybe fix the issue maybe not), could you keep testing it?