边缘世界 RimWorld

边缘世界 RimWorld

40 个评价
[DHM]Roofvent(for MultiFloors)
   
奖励
收藏
已收藏
取消收藏
Mod, 1.5
文件大小
发表于
52.993 KB
1 月 20 日 下午 12:16
1 项改动说明 ( 查看 )

订阅以下载
[DHM]Roofvent(for MultiFloors)

描述
Why can't the hot underground air be released to the outside?
Now you can!

..................................................................................................


The name is roofvent, but it's actually a ceiling air conditioner.
It's a facility to cool the air downstairs.

It's a simple mode, but it wasn't simple.

I'm thinking of modifying all the other modes that I've already created,
First of all, I made the mode I wanted to make.

I was studying z-level, but since it came out in multi floor mode,
In the direction of implanting the previously thought functions into multi floor mode
You are about to proceed with the operation.

-Feature in mind
1. Shared Tower Storage
2. Injection machine (with warcasket)
3. traps coming up from the ground
4. etc

I'm going to slowly modify the previous mod I made.
I transplanted the code I wrote, so it doesn't work.

If you have any ideas, please comment.
14 条留言
slurpme 8 月 4 日 上午 1:45 
there is a compatible dev version of the multifloor mod https://psteamcommunity.yuanyoumao.com/sharedfiles/filedetails/?id=3537626590 i would love 1.6 compatibility because this is a high quality mod also updates to to your other multifloor mods would be nice...
Fobos 3 月 25 日 下午 1:57 
I thought this mod adds more warcrimes(((((
Drilled_Head  [作者] 2 月 25 日 下午 8:36 
ShinUon : The cooler must have an empty space underneath, and the room where the cooler is installed must not have a roof. The cooler is a device that exhausts indoor air to the outdoors, and since it uses the same vanilla code, its efficiency is the same as the vanilla cooler.
ShinUon 2 月 24 日 下午 10:57 
Also, is the roofvent supposed to be visible on the floor above? I don't see any indication of where it is on the floor above where it is placed.
ShinUon 2 月 24 日 下午 10:57 
Since this is technically a cooler rather than a vent, is it limited in how much heat it can remove from a room?

I am testing in dev quicktest but it doesn't seem to be working. I made a room underground that generates a lot of heat and roofed the room. And I build a room directly above as well that is walled and roofed.

Underground room is 100+ F but after adding the roofvent/cooler, the temperature does not reduce and the room above it does not heat up either.
Drilled_Head  [作者] 1 月 26 日 下午 10:07 
漠然—琉璃 There would be no reason for bugs to occur, right? Using vanilla code.
漠然—琉璃 1 月 26 日 下午 1:21 
Can you contact the original author, I think the power and thermodynamics system should be integrated into the original mod to reduce bugs
DaCool 1 月 21 日 上午 5:50 
cool
Drilled_Head  [作者] 1 月 20 日 下午 1:36 
남블님 Yes. The features of the vanilla version are retained. It varies depending on the size of the space. However, I confirmed that it was turning red. In temperature layout.
남블님 1 月 20 日 下午 1:31 
Does the upper floor get hot?