35 条留言
Hiroshima 13 小时以前 
Still works fine
Hoschi 19 小时以前 
Anyone have any idea why the furnace is being pumped full of pressure so quickly and explodes, even though 1) the fuel pipe is only at 8 MPa, and 2) everything else is fine? It's very strange. It doesn't matter whether I turn on the two fuel pumps beforehand or not. If I select an ore and press the button, the furnace quickly increases to 60 MPa without either of the fuel pumps even turning on.
Tango80 10 月 17 日 下午 2:48 
For those people who can't get this to work there are lines in the code that have to be changed to the correct IC housing. which you are using. The default Hash IC or the Furnace IC housings are of the compact instead of the standard. To fix for standard housing the Hash IC program line to check is line 102 and make sure that it is the correct ID code for the Housing you are using i.e. -128473777 for normal housing and 2037291645 for the Compact. If they are different to what you are using this line needs to be changed. Also quite similar is line 2 on the Furnace IC program line make sure again if its -128473777 for the normal housing and 2037291645 for the compact.
Barsiel  [作者] 10 月 4 日 下午 3:16 
@storchi You just have to update the script from the work shop and it will now work with the compact IC housing.
storchi 10 月 4 日 下午 2:01 
@warsome
I´m sry, knew.
What do i have to do in the furnace code and what do i have to do in the hash IC Code.
pls eplain it like im a 5 yeat old.^^
Lord Read 10 月 4 日 上午 4:58 
@warsome oh nice thanks so much!
Warsome 9 月 30 日 上午 3:38 
@Lord Read, you just need to edit the code, and change the HASH id for the IC-Housing to the new one. (2 port is: -128473777 1 port is: 2037291645 )
Lord Read 9 月 29 日 下午 2:39 
Post Terrain Update Sept 2025, This will not work with the new ICHousing with 1 data/power port (Compact version). You must use the "Legacy" Housing with 2 ports. Took me hours to figure out.
trucksarenoisy 8 月 23 日 上午 8:41 
this script is working on the latest beta branch, i have just set it up successfully and it's working as intended
Troller o Thardigrado 6 月 8 日 上午 9:17 
I think this script doesn't work currently. Two things, even naming everything correctly, as in the explanation, the start button still doesn't start the furnace. When I turn on the IC fitting, the fuel mixer stays at 100% on output 1 and 0% on output 2, and doesn't turn off until I turn off the IC fitting.